      basic introduction

      Definition of connector: CONNECTOR. Domestically also known as connectors, plugs and sockets. Generally refers to electrical connectors. That is, a device that connects two active devices, transmitting current or signals.

      Basic performance

      The basic performance of connectors can be divided into three categories:

      1. Mechanical properties

      2. Electrical performance

      3. Environmental performance

      Common tests and reference standards

      Appearance size test

      Reference standard: EIA-364-18

      purpose:

      1. Check whether the appearance of the sample will affect the product performance or affect the product test results.

      2. Check whether the product specifications and sizes meet the product requirements and related standards or association specifications

      Plug force test

      Reference standard: EIA-364-13

      Purpose: To verify whether the insertion force of the connector meets product specifications

      Principle: fully insert or pull out the connector at the specified rate, and record the corresponding force value

      Durability test

      Reference standard: EIA-364-09

      Purpose: To evaluate the impact of repeated insertion and removal on the connector, and to simulate the actual insertion and removal of the connector

      Principle: The connector is continuously plugged and unplugged at a specified rate until the specified number of times is reached.

      Insulation resistance test

      Reference standard: EIA-364-21

      Purpose: To verify whether the insulation performance of the connector meets the requirements of the circuit design or when it is subjected to environmental stresses such as high temperature and humidity, and whether its resistance value meets the requirements of the relevant technical conditions.

      Principle: The voltage is applied to the insulated part of the connector, so that the resistance value is caused by the leakage current generated on the surface or inside of the insulated part.

      Withstand voltage test

      Reference standard: EIA-364-20

      Purpose: To verify whether the connector can work safely at rated voltage and to withstand the ability of overpotential, so as to assess whether the connector insulation material or insulation gap is appropriate. Principle: Between the connector contact and the contact, the contact Apply the specified voltage between the shells and keep it for a specified time, and observe whether the sample has a breakdown or discharge phenomenon.

      Contact resistance test

      Reference standard: EIA-364-06/EIA-364-23

      Purpose: To verify the principle of the resistance value generated when the current flows through the contact surface of the contact: By applying a prescribed current to the connector, measuring the voltage drop across the connector to obtain the resistance value

      Vibration test:

      Reference standard: EIA-364-28

      Purpose: To verify the impact of vibration on the performance of electrical connectors and their components

      Vibration type: random vibration, sinusoidal vibration

      Mechanical shock test

      Reference standard: EIA-364-27

      Purpose: To verify the impact resistance of the connector and its components or to assess whether the structure is strong

      Test waveform: half sine wave, square wave

      Thermal shock test

      Reference standard: EIA-364-32

      Purpose: To evaluate the impact of connectors on their functional quality under rapid large temperature changes

      Temperature and humidity combined cycle test

      Reference standard: EIA-364-31

      Objective: To evaluate the impact of the connector on the performance of the connector after being stored in a high temperature and high humidity environment

      High temperature test

      Reference standard: EIA-364-17

      Purpose: To evaluate whether the performance of the terminal and insulator has changed after the connector is exposed to high temperature environment for a specified time

      Salt spray test

      Reference standard: EIA-364-26

      Purpose: To evaluate the resistance of connectors, terminals and coatings to corrosion by salt spray

      Mixed gas corrosion test

      Reference standard: EIA-364-65

      Objective: To evaluate the corrosion resistance of connectors exposed to different concentrations of mixed gases and the impact on their performance

      Wire swing test

      Reference standard: EIA-364-41

      Purpose: To evaluate the ability of the connector to withstand repeated response forces and to evaluate the electrical continuity in the process

      Temperature rise test

      Reference standard: EIA-364-70

      Purpose: To evaluate whether the temperature rise of the terminal exceeds the specified value when the terminal is passing the rated current

      Our advantage

      1. With a professional qualification and experienced expert technical team, we can provide you with professional consultation and services.

      2. Have advanced laboratory equipment to ensure the accuracy and reliability of test data.

      3. As a third-party testing and certification organization trusted by customers worldwide, we are your certificate of quality.


      Online consultation

      Online consultation

      Recommend
      • Brazil ANATEL Certification

        Brazil ANATEL Certification

        ANATEL certification is a mandatory certification for telecommunications equipment or related equipment by the Brazilian National Telecommunications Administration (Agência Nacional de Telecomunica??es), including wireless communication equipment, wired communication equipment and related auxiliary equipment; this certification ensures that telecommunications equipment sold in the Brazilian market meets Brazil\'s technical standards and regulatory requirements, and guarantees the product\'s quality requirements such as radio frequency, electrical safety, electromagnetic compatibility, and electromagnetic exposure. If the product entering Brazil does not complete ANATEL certification, it may face fines, seizures, and other penalties.

      • COC certification in Algeria

        COC certification in Algeria

        COC certification in Algeria is a mandatory certification for products exported to Algeria, ensuring that the products comply with the country\'s safety, quality, and technical standards. The certification process includes document review, product testing, and factory inspection. Products that pass certification can be legally sold in the local market, protecting consumer interests and promoting fair trade.

      • Saudi Arabia GCC Certification

        Saudi Arabia GCC Certification

        GCC certification is the abbreviation for Gulf Cooperation Council certification, which is a mandatory certification requirement for products entering the market in Saudi Arabia and other countries in the Gulf region.

      Connector inspection and certification

      Definition of connector: CONNECTOR. Domestically also known as connectors, plugs and sockets. Generally refers to electrical connectors. That is, a device that connects two active devices, transmitting current or signals.

      Get a quote
      主站蜘蛛池模板: 精品人妻无码专区在中文字幕| 久热爱精品视频线路一| 好吊妞国产欧美日韩免费观看| 国产成人精品久久| 无码人妻斩一区二区三区| 亚洲AV日韩AV永久无码电影| 亚洲色拍拍噜噜噜最新网站| 国产中年熟女大集合| 精品一区二区三区无码视频| 2021国产精品视频网站| 久久精品99国产精品日本 | 国精品午夜福利视频不卡| 亚洲一区二区三区无码久久| 日本一区二区三区免费播放视频站 | 亚洲AV片一区二区三区| 香港日本三级亚洲三级| 少妇AV一区二区三区无码| 国产睡熟迷奷系列网站| 成人AV无码一区二区三区| 久久天堂综合亚洲伊人HD妓女 | 青青草无码免费一二三区| 成在线人午夜剧场免费无码| 免费人成再在线观看网站| 男人扒开女人腿桶到爽免费| 成午夜福利人试看120秒| 亚洲中文精品一区二区| 亚洲精品乱码久久久久久自慰| 国产欧美日韩亚洲一区二区三区 | 色噜噜国产精品视频一区二区| 国产中文三级全黄| 色婷婷婷亚洲综合丁香五月| JAPANESE国产在线观看播放| 成人免费A级毛片无码片2022| 中出人妻中文字幕无码| 亚洲最大成人网色| 18禁成人免费无码网站| 中文字幕在线精品国产| 性做久久久久久久久| 激情97综合亚洲色婷婷五| 人妻系列无码专区免费| 人妻一区二区三区三区|